LOSA DE CIMENTACION SAFE 2016

LOSA DE CIMENTACION SAFE 2016

Introduction to Safe and Foundation Modeling

Overview of the Process

  • Jofre introduces the session focused on using SAFE for modeling a foundation slab, emphasizing the need for a verified ETABS model.
  • The process begins with exporting building loads from ETABS to SAFE, ensuring all reactions are included in the export.
  • After importing into SAFE, users can visualize loads and reactions that were transferred from ETABS.

Material Properties Setup

  • Users set material properties such as concrete strength (250 kg/cm²) and elasticity modulus based on this strength.
  • Soil properties are defined next, including a compression modulus (K value), which is set at 5.

Load Patterns and Cases

Defining Load Patterns

  • Load patterns are created within SAFE; unnecessary patterns imported from ETABS can be deleted to streamline the model.
  • A self-weight load pattern is established for the foundation, labeled "PP font," categorized as super dead load.

Creating Load Cases

  • New load cases are generated to amplify static loads from ETABS, incorporating seismic factors into calculations.

Combining Loads and Assigning Width

Exporting Combinations

  • Users can export predefined load combinations from Excel into SAFE after creating necessary combinations in the software.

Assigning Load Width

  • To observe slab functionality accurately, it’s crucial to define widths for pedestals based on calculated dimensions.

Drawing Foundation Slab

Drawing Techniques

  • Various methods exist for drawing slabs in SAFE; area-based drawing is chosen for efficiency while considering an overhang of 1.50 m.

Defining Pedestals

  • Pedestal dimensions are specified (70 cm x 80 cm), followed by their placement across the slab area.

Assigning Loads to Slab

Surface Loads Assignment

  • Surface loads include a live load of 250 kg/m² and an additional surcharge of 300 kg/m² assigned directly onto the slab.

Design Strips Creation

Establishing Design Strips

  • Design strips are created based on recommendations regarding minimum lengths relative to pedestal spacing; these will guide reinforcement design.

Reinforcement Analysis

Selecting Reinforcement Types

  • Different types of reinforcement bars are evaluated; preferences can be adjusted according to regional standards or project requirements.

Mesh Creation and Analysis

Finalizing Mesh Settings

  • A mesh size of 30 cm is recommended before running analyses on the foundation slab model in SAFE.

Analyzing Results

Observations Post Analysis

  • Deformations observed during analysis indicate performance under various loading conditions; maximum deformation noted was around 0.15 cm under envelope conditions.

Functionality Verification

  • The functionality check reveals that if values exceed one, adjustments may be needed either by increasing thickness or modifying embedment depth.

Moment and Shear Checks

Evaluating Moments

  • Moments experienced by designed strips show significant values indicating areas needing attention during reinforcement planning.

Conclusion

Summary Remarks

  • The session concludes with insights into designing effective reinforcement strategies tailored to specific loading scenarios encountered during analysis.