Lectura de EKG
Interpretation of EKG
Basic Reading of EKG
- The EKG represents the electrical activity of the heart, recorded between positive and negative electrodes, resulting in 12 leads.
- Understanding the cardiac conduction vector is crucial; it moves from right to left, top to bottom, and back to front. This orientation helps determine which leads should be positive or negative.
Cardiac Conduction Pathway
- The conduction starts at the sinoatrial node in the right atrium, moving to the left atrium before reaching the atrioventricular node and then downwards towards the ventricles.
- It's essential to ensure that EKG machines are calibrated correctly; standard speed should be set at 25 mm per second for accurate readings.
Components of an EKG
- Key components include waves P, Q, R, S, and T:
- P wave indicates atrial depolarization.
- QRS complex signifies ventricular depolarization.
- T wave represents ventricular repolarization.
Phases of Heart Activity
- The heart undergoes several phases:
- Isovolumetric contraction (pressure increases with constant volume).
- Ejection phase (valves open).
- Isovolumetric relaxation (valves close while muscle relaxes).
Rhythm Analysis
- In sinus rhythm:
- P waves must be positive in D2, D3, and aVF.
- Each P wave is followed by a QRS complex indicating proper conduction between atria and ventricles.
- PR interval should remain consistent between 0.12 to 0.20 seconds for normal AV conduction.
Lead Derivations Overview
- Understanding lead placements:
- Lead I connects right arm (RA) and left arm (LA).
- Lead II connects LA and left leg (LL).
- Lead III connects LL and RA.
- Each lead has specific angles associated with them for interpreting cardiac axis:
- Lead I = +0°, Lead II = +60°, Lead III = +120°.
These angles help visualize cardiac orientation on an EKG strip.
Understanding Cardiac Axis and EKG Components
Defining the Normal Cardiac Axis
- The normal cardiac axis is defined between -30º and +90º, indicating a positive complex in leads D1 and ABF.
- An axis below -30º suggests left axis deviation, potentially indicating left ventricular hypertrophy or a bundle branch block.
- Conversely, an axis above +90º indicates right axis deviation, which may suggest right ventricular hypertrophy or pulmonary pathology.
Analyzing QRS Complex Variations
- The QRS complex varies based on vector conduction; if both D1 and D2 are positive, the axis is normal (between -30º and +90º).
- If D1 is positive and D2 negative, the axis lies between -30º and -90º (left deviation); if both are negative with ABF positive, it indicates extreme right deviation.
Understanding Waveforms in EKG
- The P wave represents atrial depolarization; it should be positive in most leads except V1 and AVR. Its duration must be less than 0.12 seconds.
- The RR interval reflects conduction from the atrioventricular node; it should last between 0.12 to 0.20 seconds.
Characteristics of QRS Complex
- The QRS complex signifies ventricular depolarization; its duration should be under 0.12 seconds.
- The first negative wave is the Q wave followed by R (positive), then S (negative).
Importance of ST Segment Analysis
- The ST segment should remain iso-electric; deviations can indicate coronary syndromes with or without ST elevation.
T Wave Dynamics
- The T wave indicates ventricular repolarization; it typically aligns in polarity with the preceding QRS complex.
Monitoring EKG: Clinical Correlation
Evaluating Patient Symptoms Alongside EKG Findings
- Clinical evaluation of patients must accompany EKG monitoring for accurate diagnosis—absence of a QRS complex could indicate systole but requires patient assessment for confirmation.
Identifying Complex Characteristics
- A wide QRS suggests a ventricular origin while a narrow one indicates supraventricular origin—important for diagnosing tachycardia types.
Frequency Assessment
- Heart rate classification: bradycardia (<60 bpm), tachycardia (>100 bpm). Examples illustrate differences between ventricular tachycardia (wide complexes, fast rate) versus supraventricular tachycardia (narrow complexes).
Rhythm Consistency
- Regularity in rhythm shows predictable intervals between complexes—key for distinguishing types of tachycardias effectively.
Understanding Defibrillable and Non-Defibrillable Rhythms
Defibrillable Rhythms
- The discussion begins with the identification of defibrillable rhythms, highlighting that a high frequency and wide QRS complexes indicate potential issues. An irregular rhythm suggests fibrillation.
- Ventricular fibrillation without pulse is introduced as a critical condition characterized by disorganized electrical activity, leading to unpredictable heartbeats.
- This type of fibrillation results in a heart rate exceeding 300 beats per minute, causing hemodynamic instability due to insufficient blood flow to the body.
- Normal heart rates range from 60 to 100 beats per minute; excessively rapid rates hinder ventricular filling, resulting in ineffective pulses and inadequate oxygen delivery.
- Multiple entry circuits cause chaotic electrical activity, often associated with acute myocardial ischemia or structural coronary disease.
Ventricular Tachycardia Without Pulse
- The speaker emphasizes the importance of clinical assessment alongside monitoring; an EKG showing tachycardia must be correlated with patient symptoms for accurate diagnosis.
- Ventricular tachycardia is defined by wide QRS complexes at a rapid and rhythmic pace, leading to inefficient contractions and low cardiac output.
- The absence of detectable pulses indicates severe hemodynamic impact due to reduced oxygenation and glucose perfusion throughout the body.
- Key characteristics include dissociation between atrial and ventricular contractions, which may present as fusion or capture beats on an EKG.
Non-Defibrillable Rhythms
Asystole
- Asystole is described as complete absence of electrical activity in the heart, necessitating immediate CPR since there’s no effective blood circulation.
- Recognizing asystole involves identifying a flat line on the monitor; this indicates no cardiac contraction or pulse presence.
Electrical Activity Without Pulse
- This condition may appear normal on an EKG but lacks corresponding pulses; continuous patient evaluation is crucial despite monitor readings suggesting otherwise.
- The absence of response from the patient despite apparent electrical activity signifies critical underlying issues requiring urgent intervention.